EVI Low Ambient Temperature Heat Pump

EVI Low Ambient Temperature Heat Pump
Product Detailed
Low ambient temperature -25 C available, high COP EVI technology heating,and domestic sanitary hot water supply

 Name: EVI Low Ambient Temperature Heat Pump

Modelheat pumpCAR-24EVI
Standard conditionHeating capacitykw20.80
kcal/h17885.00
Hot water supplyT/h0.45
Input powerkw5.12
Low temperature conditionsHeating capacitykw17.30
kcal/h14875.00
Hot water supplyT/h0.33
Input powerkw5.20
Ultra-low temperature conditionsHeating capacitykw10.66
kcal/h9166.00
Hot water supplyT/h0.20
Input powerkw5.00
Standard condition heating input currentA24.40
Max running currentA34.20
PowerV/Ph/Hz220V~50Hz
Unit Noise comprehensive indexDb(A)58.00
DimensionWmm1390/900(side)
Dmm635/420(side)
Hmm950/1400(side)
Unit weightkg175.00
Water temperature control precision°C±2°C
Ambient temperature range°C–25°C–43°C
Throttle type thermostatic expansion valve
RefrigerantType R407C
Refrigerant chargekg2.6*2
Max working pressurebar28.00
CompressorType Efficient fully enclosed type vortex
Qtypc2.00
Stall CurrentA60.00
Air-source side heat exchangerType Finned heat exchanger
Qtypc2.00
Motor powerkw0.40
Hhot water side heat exchangerType Finned heat exchanger
Water flowm3/h3.58
Water pressure downkPa30.00
Connecting pipe sizeDN25.00
Water side max working pressurekPa1000.00
Suggestion water tank volumem32.5–4

1,standard condition heating condiiton: air source side heat exchanger inlet air 20/15°C,hot water source intial temp 15°C,end heating temp 55°C.2,Low temp heating condition: air source side heat exchanger inlet air 7/6°C,hot water side intial temp 10°C,end heating temp 55°C.3,Ultra-low temperature heating conditions:air-source side heat exchanger inlet air -15/-17°C,hot water side intial temp 10°C,end heating temp 55°C.

EVI Low Ambient Temperature Heat Pump



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.