EVI low temperature heat pump water heater

EVI low temperature heat pump water heater
Product Detailed
Low ambient temperature -25 C available, high COP EVI technology heating,and domestic sanitary hot water supply

Name:EVI  low temperature heat pump water heater

Modelheat pumpCAR-80EVI
Standard conditionHeating capacitykw81.20
kcal/h69819.00
Hot water supplyT/h1.75
Input powerkw19.20
Low temperature conditionsHeating capacitykw66.40
kcal/h57094.00
Hot water supplyT/h1.27
Input powerkw18.76
Ultra-low temperature conditionsHeating capacitykw38.80
kcal/h33362.00
Hot water supplyT/h0.74
Input powerkw19.60
Standard condition heating input currentA34.00
Max running currentA48.00
PowerV/Ph/Hz380V/3N/50Hz
Unit Noise comprehensive indexDb(A)66.00
DimensionWmm1700.00
Dmm900.00
Hmm1250.00
Unit weightkg620.00
Water temperature control precision°C±2°C
Ambient temperature range°C–25°C–43°C
Throttle type thermostatic expansion valve
RefrigerantType R407C
Refrigerant chargekg3.5*4
Max working pressurebar28.00
CompressorType Efficient fully enclosed type vortex
Qtypc2.00
Stall CurrentA60.00
Air-source side heat exchangerType Finned heat exchanger
Qtypc2.00
Motor powerkw0.75*2
Hhot water side heat exchangerType Finned heat exchanger
Water flowm3/h13.96
Water pressure downkPa48.00
Connecting pipe sizeDN50.00
Water side max working pressurekPa1000.00
Suggestion water tank volumem310–16

1,standard condition heating condiiton: air source side heat exchanger inlet air 20/15°C,hot water source intial temp 15°C,end heating temp 55°C.2,Low temp heating condition: air source side heat exchanger inlet air 7/6°C,hot water side intial temp 10°C,end heating temp 55°C.3,Ultra-low temperature heating conditions:air-source side heat exchanger inlet air -15/-17°C,hot water side intial temp 10°C,end heating temp 55°C.